  "package": "hyper-ontology/1",
  "designed_with": "Praxis",
  "implemented_with": "Hyper Ontology",
  "paper": {
    "title": "Pit Camera Watch: An On-Premises Camera Monitoring System for Every Turn, Crossing and Pit Entry on the Test Site",
    "url": "https://codeatoms.ai/test-site-camera-monitoring-us/",
    "doi": "10.5281/zenodo.23296077"
  },
  "sector": "discrete-manufacturing-and-automotive",
  "country": "United States",
  "scenario": "the operator is described by class, never by name: a vehicle proving ground in the United States",
  "source": "chapter 5 of the paper (5.1 objects, 5.3 recorded form) and Figure 4 (cards and typed links as drawn); Figure 4 counts 13 typed links and draws 13 lines, one of them (camera head to underground fiber run) without a label, named 'streams over' here after chapter 5's trace from clip to fiber strand; property lists the figure truncates are kept as drawn",
  "write_paths": [
    "the safety office export into the archive's export log, the only write path into the evidence chain",
    "detector model version changes only under site change control"
  ],
  "human_loop": "booth operators watch named views and decide; gate officers hold drop authority at each safety gate; the safety office reviewer holds download authority over the archive; nothing raises an automated alarm",
  "objects": [
    {
      "id": "the-site",
      "label": "The site",
      "kind": "site",
      "anchored_in": "",
      "properties": [
        "Turn count",
        "The pit access",
        "The area",
        "Posted speed"
      ],
      "status_vocabulary": [],
      "links": [
        {
          "to": "the-site-operator",
          "label": "staffed by"
        },
        {
          "to": "the-operator-s-own-system-power-fiber-assessment-package",
          "label": "assessed by"
        }
      ]
    },
    {
      "id": "camera-pole",
      "label": "Camera Pole",
      "kind": "asset",
      "anchored_in": "the recorder's configuration under site change control",
      "properties": [
        "Pole number",
        "Voltage class (277/120/24 V)",
        "Fiber strand"
      ],
      "status_vocabulary": [],
      "links": []
    },
    {
      "id": "camera-head",
      "label": "Camera Head",
      "kind": "asset",
      "anchored_in": "the recorder's configuration under site change control",
      "properties": [
        "ONVIF profile",
        "Resolution",
        "Mount height"
      ],
      "status_vocabulary": [
        "Streaming",
        "Degraded",
        "Offline"
      ],
      "links": [
        {
          "to": "camera-pole",
          "label": "mounts on"
        },
        {
          "to": "vehicle-under-test",
          "label": "observes"
        },
        {
          "to": "underground-fiber-run",
          "label": "streams over"
        }
      ]
    },
    {
      "id": "underground-fiber-run",
      "label": "Underground Fiber Run",
      "kind": "asset",
      "anchored_in": "the recorder's configuration under site change control",
      "properties": [
        "Strand count",
        "NEMA box rating",
        "FODP port"
      ],
      "status_vocabulary": [
        "Installed",
        "Tested",
        "Damaged",
        "Repaired"
      ],
      "links": [
        {
          "to": "recorder-server",
          "label": "terminates at"
        }
      ]
    },
    {
      "id": "safety-gate",
      "label": "Safety Gate",
      "kind": "asset",
      "anchored_in": "the recorder's configuration under site change control",
      "properties": [
        "Gate id",
        "Reaction lag",
        "Drop button"
      ],
      "status_vocabulary": [],
      "links": [
        {
          "to": "gate-officer",
          "label": "operated by"
        }
      ]
    },
    {
      "id": "operator-booth-display",
      "label": "Operator Booth Display",
      "kind": "asset",
      "anchored_in": "the recorder's configuration under site change control",
      "properties": [
        "Display id",
        "Layout",
        "Assigned views"
      ],
      "status_vocabulary": [],
      "links": []
    },
    {
      "id": "recorder-server",
      "label": "Server (the operator's own system)",
      "kind": "system",
      "anchored_in": "the recorder's configuration under site change control",
      "properties": [
        "Role (primary/failover)",
        "HDD"
      ],
      "status_vocabulary": [],
      "links": []
    },
    {
      "id": "30-day-footage-archive",
      "label": "30-Day Footage Archive",
      "kind": "record",
      "anchored_in": "the recorder's configuration under site change control",
      "properties": [
        "Retention days",
        "Role-over rule",
        "Export log"
      ],
      "status_vocabulary": [],
      "links": []
    },
    {
      "id": "incident-accident-record",
      "label": "Incident/Accident Record",
      "kind": "record",
      "anchored_in": "the recorder's configuration under site change control",
      "properties": [
        "Date",
        "Cameras cited",
        "Exported clips"
      ],
      "status_vocabulary": [],
      "links": [
        {
          "to": "safety-office-reviewer",
          "label": "reviewed by"
        },
        {
          "to": "safety-gate",
          "label": "cites"
        },
        {
          "to": "30-day-footage-archive",
          "label": "links to"
        }
      ]
    },
    {
      "id": "the-site-operator",
      "label": "The site Operator",
      "kind": "person",
      "anchored_in": "the operator's identity policy",
      "properties": [
        "Shift",
        "Certification",
        "Booth position"
      ],
      "status_vocabulary": [],
      "links": [
        {
          "to": "operator-booth-display",
          "label": "assigned to"
        }
      ]
    },
    {
      "id": "gate-officer",
      "label": "Gate Officer",
      "kind": "person",
      "anchored_in": "the operator's identity policy",
      "properties": [
        "Gate assignment",
        "Drop authority"
      ],
      "status_vocabulary": [],
      "links": []
    },
    {
      "id": "safety-office-reviewer",
      "label": "Safety Office Reviewer",
      "kind": "person",
      "anchored_in": "the operator's identity policy",
      "properties": [
        "Download authority",
        "Review queue"
      ],
      "status_vocabulary": [],
      "links": []
    },
    {
      "id": "vehicle-under-test",
      "label": "Vehicle Under Test",
      "kind": "asset",
      "anchored_in": "the operator's test schedule",
      "properties": [
        "Vehicle type",
        "Test program"
      ],
      "status_vocabulary": [],
      "links": [
        {
          "to": "test-cycle",
          "label": "runs within"
        }
      ]
    },
    {
      "id": "test-cycle",
      "label": "Test Cycle",
      "kind": "event",
      "anchored_in": "the operator's test schedule",
      "properties": [
        "Start time",
        "Route",
        "Turns exercised"
      ],
      "status_vocabulary": [
        "Planned",
        "Running",
        "Aborted",
        "Complete"
      ],
      "links": [
        {
          "to": "30-day-footage-archive",
          "label": "recorded in"
        }
      ]
    },
    {
      "id": "the-operator-s-own-system-power-fiber-assessment-package",
      "label": "The operator's own system Power/Fiber assessment package",
      "kind": "document",
      "anchored_in": "the operator's own system, read only",
      "properties": [
        "Power loads per pole",
        "Fiber"
      ],
      "status_vocabulary": [],
      "links": []
    }
  ]
}