  "package": "hyper-ontology/1",
  "designed_with": "Praxis",
  "implemented_with": "Hyper Ontology",
  "paper": {
    "title": "Loop Integrity Watch: Ending Distorted Radar Level Readings and Tank-to-Tank Swapping Across the Tank Farm",
    "url": "https://codeatoms.ai/tank-gauge-integrity-pakistan/",
    "doi": "10.5281/zenodo.23157967"
  },
  "sector": "oil-and-gas",
  "country": "Pakistan",
  "scenario": "the operator is described by class, never by name; the design answers a public requirement in this sector",
  "source": "chapter 5 of the paper and Figure 4 (typed links as drawn); properties and status vocabularies from the plan the paper was drawn from; Figure 4's title counts 14 typed links and draws 15 lines, all kept here; the location engineer is drawn in Figure 4 and named in chapter 5",
  "write_paths": [
    "the integrity monitor writes data quality events and status changes into the model; readings are never written by the design",
    "gauging host configuration changes only under the OEM authorization letter and the operator's change control"
  ],
  "human_loop": "every data quality event moves from open to acknowledged to resolved under a named person; a named technician is assigned to each loop and the location engineer signs acceptance",
  "objects": [
    {
      "id": "tank",
      "label": "Fuel Tank",
      "kind": "asset",
      "anchored_in": "centralized gauging software",
      "properties": [
        "Tank number (TK-xxx)",
        "Section (gasoline or kerosene)",
        "Loop assignment",
        "Product stored",
        "Capacity",
        "Current level"
      ],
      "status_vocabulary": [
        "Reading",
        "Distorted",
        "Swapped",
        "Offline"
      ],
      "links": [
        {
          "to": "reading",
          "label": "records"
        },
        {
          "to": "dq_event",
          "label": "raises on"
        },
        {
          "to": "picture",
          "label": "projects"
        }
      ]
    },
    {
      "id": "rtg",
      "label": "Radar Tank Gauge (RTG)",
      "kind": "asset",
      "anchored_in": "centralized gauging software",
      "properties": [
        "Modbus slave address",
        "Loop number",
        "OEM",
        "Last reading timestamp",
        "Signal quality"
      ],
      "status_vocabulary": [
        "Healthy",
        "Degraded",
        "No response"
      ],
      "links": [
        {
          "to": "tank",
          "label": "measures"
        },
        {
          "to": "loop",
          "label": "",
          "note": "drawn in Figure 4 without a label"
        }
      ]
    },
    {
      "id": "loop",
      "label": "RTG Communication Loop",
      "kind": "asset",
      "anchored_in": "loop wiring records",
      "properties": [
        "Loop number (Loop01-03)",
        "Tanks served",
        "Booster count",
        "Segment length",
        "Terminating resistance"
      ],
      "status_vocabulary": [
        "Healthy",
        "Degraded",
        "Failed"
      ],
      "links": [
        {
          "to": "reading",
          "label": "arrives over"
        },
        {
          "to": "dq_event",
          "label": "names"
        },
        {
          "to": "asbuilt",
          "label": "documented by"
        }
      ]
    },
    {
      "id": "booster",
      "label": "Modbus Booster (Repeater)",
      "kind": "asset",
      "anchored_in": "the service order",
      "properties": [
        "OEM",
        "Serial number",
        "Loops served",
        "Supply voltage 24VDC",
        "Commissioning date"
      ],
      "status_vocabulary": [
        "In warranty",
        "Out of warranty",
        "Failed"
      ],
      "links": [
        {
          "to": "loop",
          "label": "repeats"
        }
      ]
    },
    {
      "id": "exjb",
      "label": "Explosion Proof Junction Box",
      "kind": "asset",
      "anchored_in": "site hazardous-area register",
      "properties": [
        "Protection concept (Eex'n')",
        "Location section",
        "Contents (repeater, PSU, breakers, marshalling)",
        "Certificate reference"
      ],
      "status_vocabulary": [],
      "links": []
    },
    {
      "id": "reading",
      "label": "Gauge Reading",
      "kind": "measure",
      "anchored_in": "centralized gauging software",
      "properties": [
        "Timestamp",
        "Level",
        "Temperature",
        "Quality flag",
        "Source loop"
      ],
      "status_vocabulary": [],
      "links": []
    },
    {
      "id": "dq_event",
      "label": "Data Quality Event",
      "kind": "event",
      "anchored_in": "the integrity monitor",
      "properties": [
        "Tank",
        "Event type (stuck value, swapped data, distortion,",
        "Detected at",
        "Cleared by",
        "Loop affected"
      ],
      "status_vocabulary": [
        "Open",
        "Acknowledged",
        "Resolved"
      ],
      "links": [
        {
          "to": "picture",
          "label": "aggregates"
        }
      ]
    },
    {
      "id": "picture",
      "label": "Central Inventory Picture",
      "kind": "system",
      "anchored_in": "the system of context",
      "properties": [
        "Tanks covered",
        "Data availability",
        "Open quality events",
        "Last sync"
      ],
      "status_vocabulary": [],
      "links": []
    },
    {
      "id": "asbuilt",
      "label": "Loop Wiring As-Built",
      "kind": "document",
      "anchored_in": "loop wiring records",
      "properties": [
        "Loop number",
        "Cable schedule",
        "Gland schedule",
        "Signal levels recorded",
        "Revision"
      ],
      "status_vocabulary": [
        "Draft",
        "Issued for construction",
        "As-built"
      ],
      "links": []
    },
    {
      "id": "service_order",
      "label": "Service Order",
      "kind": "record",
      "anchored_in": "the operator's procurement record",
      "properties": [
        "Public reference",
        "Order number",
        "Issue date",
        "90-day completion deadline",
        "Invoice number"
      ],
      "status_vocabulary": [
        "Issued",
        "In progress",
        "Completed"
      ],
      "links": [
        {
          "to": "booster",
          "label": "authorizes"
        }
      ]
    },
    {
      "id": "warranty",
      "label": "Warranty and Support Record",
      "kind": "record",
      "anchored_in": "the service order",
      "properties": [
        "Equipment covered",
        "Start date",
        "12-month end date",
        "Support tickets",
        "Resolution times"
      ],
      "status_vocabulary": [
        "Expired"
      ],
      "links": [
        {
          "to": "service_order",
          "label": "",
          "note": "drawn in Figure 4 without a label"
        }
      ]
    },
    {
      "id": "auth_letter",
      "label": "OEM Authorization Letter",
      "kind": "document",
      "anchored_in": "the OEM",
      "properties": [
        "Issued by the host's OEM",
        "Service provider named",
        "Scope of authorization",
        "Validity"
      ],
      "status_vocabulary": [],
      "links": [
        {
          "to": "warranty",
          "label": "",
          "note": "drawn in Figure 4 without a label"
        }
      ]
    },
    {
      "id": "hse_permit",
      "label": "HSE Work Permit",
      "kind": "record",
      "anchored_in": "the operator's HSE permit system",
      "properties": [
        "Permit type",
        "Work location",
        "Validity window",
        "Isolation reference",
        "Issuer"
      ],
      "status_vocabulary": [
        "Requested",
        "Issued",
        "Closed"
      ],
      "links": [
        {
          "to": "exjb",
          "label": "governs"
        }
      ]
    },
    {
      "id": "tech",
      "label": "Instrumentation Technician",
      "kind": "person",
      "anchored_in": "the service provider's roster",
      "properties": [
        "Name",
        "Employer",
        "Ex competence",
        "Assigned loop"
      ],
      "status_vocabulary": [],
      "links": [
        {
          "to": "booster",
          "label": "maintains"
        }
      ]
    },
    {
      "id": "location_engineer",
      "label": "Location Engineer",
      "kind": "person",
      "anchored_in": "the operator's directory",
      "properties": [
        "Name",
        "Section",
        "Approval authority",
        "Acceptance sign-off"
      ],
      "status_vocabulary": [],
      "links": []
    }
  ]
}