  "package": "hyper-ontology/1",
  "designed_with": "Praxis",
  "implemented_with": "Hyper Ontology",
  "paper": {
    "title": "Turbine Island Watch: Condition Monitoring and Diagnostics for a Combined Cycle Plant in Pakistan",
    "url": "https://codeatoms.ai/steam-turbine-condition-monitoring-pakistan/",
    "doi": "10.5281/zenodo.23365092"
  },
  "sector": "energy-and-utilities",
  "country": "Pakistan",
  "scenario": "the operator is described by class, never by name: a grid-connected generation company in Pakistan rehabilitating a steam turbine generator at a combined cycle plant",
  "source": "chapter 5 of the paper (the object list and its typed-link prose) and the plan the paper was drawn from; Figure 5 draws the generic object grammar, so the typed links are written from chapter 5 sentences and labelled as they read there",
  "write_paths": [
    "condition work orders written to the document management system through its own interface",
    "the alert status ladder, advanced only by the shift operator or the warranty engineer"
  ],
  "human_loop": "every alert carries a prescribed action that a named shift operator acknowledges; the platform advises and the protection layer trips; no write to the DCS",
  "objects": [
    {
      "id": "steam-turbine",
      "label": "Steam Turbine STG-1",
      "kind": "asset",
      "anchored_in": "the DCS",
      "properties": [
        "KKS tag",
        "ISO 20816 Zone A/B vibration band per bearing",
        "operating hours since overhaul",
        "HEI damage item status"
      ],
      "status_vocabulary": [
        "rehabilitated",
        "commissioning",
        "reliability test",
        "performance test",
        "operating",
        "trip"
      ],
      "links": []
    },
    {
      "id": "stg",
      "label": "New Steam Turbine Generator (280 MW, 20 kV hydrogen-cooled)",
      "kind": "asset",
      "anchored_in": "the DCS",
      "properties": [
        "MCR rating",
        "hydrogen pressure",
        "rotor winding short-circuit detection status",
        "excitation system state"
      ],
      "status_vocabulary": [
        "installed",
        "pre-commissioning",
        "synchronised",
        "operating",
        "trip"
      ],
      "links": [
        {
          "to": "steam-turbine",
          "label": "driven by"
        }
      ]
    },
    {
      "id": "vibration-rack",
      "label": "3500 Vibration Monitoring Rack",
      "kind": "asset",
      "anchored_in": "the DCS",
      "properties": [
        "channel list",
        "probe health",
        "alarm setpoints"
      ],
      "status_vocabulary": [
        "rehabilitated",
        "calibrated",
        "online",
        "degraded"
      ],
      "links": [
        {
          "to": "steam-turbine",
          "label": "monitors bearings of"
        },
        {
          "to": "calibration-record",
          "label": "channel proven by"
        }
      ]
    },
    {
      "id": "anomaly-alert",
      "label": "Condition Anomaly Alert",
      "kind": "event",
      "anchored_in": "Hyper Ontology",
      "properties": [
        "source channel and KKS tag",
        "trigger threshold or model",
        "severity (ISO 20816 zone)",
        "prescribed action",
        "acknowledgement timestamps"
      ],
      "status_vocabulary": [
        "raised",
        "acknowledged",
        "in review",
        "prescribed",
        "closed",
        "false positive"
      ],
      "links": [
        {
          "to": "vibration-rack",
          "label": "raised from the channel on"
        },
        {
          "to": "steam-turbine",
          "label": "on asset"
        },
        {
          "to": "work-order",
          "label": "closed by"
        },
        {
          "to": "commissioning-test",
          "label": "closed out by"
        }
      ]
    },
    {
      "id": "work-order",
      "label": "Condition Work Order",
      "kind": "record",
      "anchored_in": "Document Management System",
      "properties": [
        "linked alert",
        "priority from the specification's list",
        "corrective measure",
        "closure evidence"
      ],
      "status_vocabulary": [
        "raised",
        "approved",
        "in progress",
        "completed",
        "verified"
      ],
      "links": [
        {
          "to": "warranty-engineer",
          "label": "attached engineer"
        }
      ]
    },
    {
      "id": "calibration-record",
      "label": "Instrument Calibration Record",
      "kind": "record",
      "anchored_in": "Document Management System",
      "properties": [
        "instrument KKS tag",
        "calibration date",
        "pass or fail result",
        "next due date"
      ],
      "status_vocabulary": [
        "due",
        "passed",
        "failed",
        "replaced"
      ],
      "links": []
    },
    {
      "id": "commissioning-test",
      "label": "Commissioning and Performance Test Record",
      "kind": "record",
      "anchored_in": "Document Management System",
      "properties": [
        "test type",
        "AGPO against GGPO result",
        "trip root-cause findings",
        "approval status"
      ],
      "status_vocabulary": [
        "procedures submitted",
        "approved",
        "executed",
        "shortfall",
        "passed"
      ],
      "links": []
    },
    {
      "id": "shift-operator",
      "label": "Shift Operator (Employer's operational personnel)",
      "kind": "actor",
      "anchored_in": "the DCS",
      "properties": [
        "PTW authorisations held",
        "units under watch",
        "acknowledgement authority"
      ],
      "status_vocabulary": [],
      "links": [
        {
          "to": "anomaly-alert",
          "label": "acknowledges"
        }
      ]
    },
    {
      "id": "warranty-engineer",
      "label": "Warranty Engineer (Contractor, DLP)",
      "kind": "actor",
      "anchored_in": "Document Management System",
      "properties": [
        "assigned defects",
        "response due dates",
        "corrective actions owned"
      ],
      "status_vocabulary": [],
      "links": []
    },
    {
      "id": "unit-availability",
      "label": "STG-1 Availability (RTR-derived)",
      "kind": "measure",
      "anchored_in": "the DCS",
      "properties": [
        "hours at base load in 72-hour window",
        "trips during RTR",
        "GGPO shortfall magnitude"
      ],
      "status_vocabulary": [],
      "links": [
        {
          "to": "steam-turbine",
          "label": "derived for"
        }
      ]
    }
  ]
}